OPERATIONAL |
|
|
 |
Conveyor Speed
|
 |
No Limit |
 |
Material top size
|
 |
Up to 400mm, typically |
 |
Bed depth range
|
 |
20 - 400mm depending on material |
 |
Range
|
 |
Moisture: 0 - 50% / Ash: Unlimited |
 |
Measurement
|
 |
Instantaneous, user selectable readout time |
 |
Instrument
Precision
|
 |
Ash in typical raw coal typically +/-0.9% |
| |
|
 |
Ash in typical washed coal typically +/- 0.6% |
| |
|
 |
Moisture: Typically 0.3% at 1 std dev |
| |
|
|
|
| |
ELECTRICAL
REQUIREMENTS |
|
|
 |
At Electronics
Control Cabinet |
 |
240 or 110 volt, single phase, 2 amp supply |
| |
|
|
|
| |
ENVIRONMENTAL REQUIREMENTS |
|
|
 |
Operating
Temperatures
|
 |
0 - 45°C, with protection
from direct sun and rain |
 |
Humidity
|
 |
0 - 95%, relative humidity (non condensing) |
| |
|
|
Note: All units are protected
against dust and moisture to IP 65 rating. |
| |
|
|
|
| |
RADIATION
LEVELS |
|
|
 |
100uSv/hr
|
 |
Maximum radiation dose rate at all
points except in direct beam |
| |
|
|
|
| |
OUPUTS
FROM THE ASHSCAN DUO |
|
|
 |
Instantaneous
Moisture and Ash |
 |
Isolated 4 - 20mA current loops
indicating the rolling average of moisture and ash
content over any accumulated time period. |
 |
System running
|
 |
Relay closure indicating that no
alarm conditions exist. |